PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Type: Temperature Signal Isolator
Measuring Medium: Temperature
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Address
Room 1311, 3f, Tianlong Plaza, Heyedi Street, Shushan District, Hefei, Anhui, China
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
  • PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Selection Table
  • Outline Dimension
  • Installation Instructions
Overview

Basic Info.

Model NO.
HGTC Temperature Signal Isolator
Display Type
Temperature Signal Isolator
Site Display
Site Display
Accuracy
≤0.2% F.S.
IP Rating
IP65
Certification
CE
Customized
Customized
Model
Hgtc
Input Signal
Thermocouple & Rtd Signal
Output Signal
4~20mA 0~5V 0~10V...
Power
18~32VDC & 18~32VDC
Channels 1
1 in 1 out
Channels 2
1 in 2 out
Channels 3
2 in 2 out
Accuracy Class
±0.1%F.S(25℃±2℃)
Response Time
≤500ms
Temperature Drift
40 Ppm / Deg.C
Output Load Capacity
600Ω
Insulation Resistance
2500 V AC
Keywords 1
Temperature Signal Isolator
Keywords 2
Temperature Signal Converter
Keywords 3
Temperature Analog Signal Isolator
Transport Package
1kg
Specification
15*10*10cm
Trademark
Siko Instruments
Origin
China
HS Code
9030339000
Production Capacity
999 Units / Weeks

Packaging & Delivery

Package Size
15.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

Pt100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator

 
* Din Rail / Panel Mount Installation.

* It Converts The Temperature Signal From Motor Or AC Transformer Into Isolated Current Or Voltage Signal Such As 4-20mA DC,  0-10V DC. And The Input,  Output,  Power Supply Are Electrically Isolated Mutually.

* It Can Be Used Togther With Modular Instrumentation And DCS,  PLC And Other Systems To Offer Signal Isolation,  Conversion,  Processing And Other Functions To The Field Instruments.

* Feature Of AC 220V Power,  Small Size,  Fast Response Time And Low Power Consumption.

    This Apparatus Transmits The In Thermocouple (Tc) Or Thermal Resistance (Rtd) Signal To Isolated Current Or Voltage Signal In A Circuit Or Two Isolated Circuits, And The Input, Output, And Power Supply Are Galvanically Isolated From Each Other.
   It Can Be Used Together With Modular Instrumentation And DCS, PLC And Other Systems, To Offer Signal Isolation, Signal Conversion, Signal Distribution, Signal Processing And Other Functions To Field Instrument, Thereby Enhancing The Immunity Of Automatic Control System In The Industrial Production Process, And Ensuring System Stability And Reliability. This Product Has Many Varieties, Such As 1 In/1 Out, 1 In/2 Out,,2 In/2 Out, With Input/Output Magnetic Isolation.
    Compared With Other Similar Products, This Apparatus Has The Advantages Of Fast Response Time, Low Power Loss And Quite Well Temperature Characteristics.

 
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator


 
Product Parameters
 
   Input Thermocouple / Rtd Signal, Isolated And Converted Into Current / Voltage Signal Or 1: 1 Thermocouple / Thermal Resistance Signal Output. The Three Terminals Of Input & Output & Power Are Photoelectrically Isolated. It'S Intelligent Temperature Signal Converter With Online Fault Self-Diagnosis Function,A Advantages Of Fast Response Speed, Low Power Consumption, And Good Temperature Characteristics.
 
   It Can Be Used In Conjunction With Modular Meters And DCS, PLC And Other Systems To Provide Signal Isolation, Signal Conversion, Signal Distribution, And Signal Processing Functions For Field Instruments, Which Enhances The Anti-Interference Ability Of The Automatic Control System In The Industrial Production Process, Ensuring The Stability And Reliability.


 
Input Terminal:  
Input Signal - RTD  RTD: Pt100, Pt1000, Cu50, Cu100, BA1, BA2 ...
Input Signal - Thermocouple  Thermocouple: K, E, S, B, J, T, R, N, WRe3-WRe25,WRe5-WRe26....
Frequency Range:  40-60Hz
Output Terminal:  
Signal Type:  0(4)mA - 20mA
 0(1)V - 5V
 0(1)V - 10V
 1:1 Thermocouple
 RTD Signal
Output Load Resistance:  Current: 4-20mA:≤600Ω &  0-±10mA:≤1KΩ
 Voltage: 0(1)-5V:≥1MΩ  &  0-10V:≥2MΩ
Basic Parameters:  
Power Supply:  DC 18-32V
 AC 85-265V
Rated Power
Consumption:
 ≤1W(1 In 1 Out & DC24V Power & Output 20mA)
 ≤1.5W(1 In 1 Out & AC220V Power & Output 20mA)
Accuracy:  ≤0.1% F.S.
Temperature Drift:  0.02% F.S./ºC (-30ºC-+85ºC)
Response Time:  ≤400ms (0-90%)(TYP)
Insulation Grade:  2000V AC/1Min (Input & Output & Power Mutually)
Insulation Resistance:  ≥100MΩ (Input & Output & Power Mutually)
Working Temperature:  -30ºC-+85ºC
EMC:  Comform To GB/T 18268.1 (IEC61326-1)
Response Time  500ms
Temperature Drift  400 ppm/Deg.C
Channels   1 Input 1 Output
 1 Input 2 Output
 2 Input 2 Output
 
Detailed Photos

PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator

PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator
PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator

 

Selection Table
  
Selection Table
HDTC- X X X X  
Channels 1       One In One Out
2       One In Two Out
5       Two In Two Out
Input Signal P1     PT100 (-200-+650ºC)
P2     PT1000 (-200-+650ºC)
C     CU50 (-50-+150ºC)
B     B (-50-+1800ºC)
K     K (-50-+1300ºC)
S     S (0-+1600ºC)
Z     Other
Output Signal   1   4-20mA
  2   0-20mA
  5   0-5V
  6   0-10V
  7   1:1 RTD
  8   1:1 Thermocouple
  Z   Other
Power Supply   DC 18-32V   
A 85-265VAC/DC
 
Outline Dimension

PT100 Input 4-20mA Output Thermal Resistance Temperature Signal Converter Isolator

Installation Instructions

A. 35mm Din Rail Mounting.  Please Make Sure The Transducer Snaps On The Rail Steadily And Firmly.

B. Vertical Installation Shall Be Kept As Possible To Facilitata Heat Dissipation.

C. Installation Position Shall Not Be Affected By Strong Mechanical Vibration,  Impact And Electromagnetic Induction From Signal Terminal And Power Supply,  Should Conformity With The Requirements On Electromagnetic Interference Resistance Of Products In Class 3 Industrial Field Atmosphere Stipulated In Iec 61000-4,  And The Atmosphere Shall Be Free From Gases That Are Corrosive To Metal And Plastic Components.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.