LCD Display High Accuracy RS 485 Low Hydrogen Gas Mass Flow Controller
01. Mass Flow Meter: Mass Flow Meter (MFM), A Mass Series Instrument Is A Direct Measurement Of Gas Mass Flow Using Capillary Heat Sensing Technology. No Need For Temperature And Pressure Correction. Mfm With High Precision And Widely Applicated In Different Industrial Fields.
02. Mass Flow Controller: Mass Flow Controller (MFC), Is A Analog And Digital Compatiable Mode Gas Mass Flow Controller, Not Only Has The Function Of MFM (Mass Flow Meter) For Direct Measurement Of Gas Mass Flow, But Also Can Automatically Control And Keep The Gas Flow At A Constant Setted Value.
MFC Can Be Adjusted By Analog Or Digital Display Controller Or Instrument Panel, Or PLC To Set And Display Instantaneous Flow.
Place of Origin |
Hefei City Anhui Province China |
Warranty |
1 Year |
Customized Support |
OEM, ODM, OBM, Software Reengineering |
Brand Name |
Siko Instruments Gas Mass Flow Controller |
Model Number |
HG-MFC Thermal Gas Mass Flow Controller |
Item |
MFM (Gas Mass Flow Meter )
MFC (Gas Mass Flow Controller) |
Flow Rate |
10sccm-200slm
300slm-3000slm |
Accuracy |
±1.0%F.S. |
Analog Output |
0-5V / 4-20mA / 0-10V |
Digital Communication |
RS485 Modbus RTU Communication |
Power |
±15V / 24V |
Process Connection |
1/4" & 3/8" & 6mm & 10mm |
Electrical Connection |
DB15 Mass Flow Controller Gas |
Base Material |
SS 316L |
Application:
01. |
Gas Flow Control |
07. |
Gas Flow Measure |
02. |
Fuel Cell & Solar Energy |
08. |
Medical Equipment |
03. |
Burner Control |
09. |
Vacuum Coating |
04. |
Gas Distrubution |
10. |
Analysis And Environmental Measurements |
05. |
Glass Industry |
11. |
Coal Metallurgy |
06. |
Semiconductor Processing |
12. |
Surface Treatment Installations |
Features
01 |
Direct Measurement Of Gas Mass Flow. |
02 |
Accuracy: ±1.0% F.S. Repeatability: ±0.25%F.S. |
03. |
Linear analogue Output Output 4-20mA, 0-5V, 0-10V etc. |
04. |
RS-232 Interfaces With PLC Or Workstation. |
05. |
RS-485 Modbus RTU (Addressable) Can Be Controlled And Displayed By Computer. |
06. |
No Need For Pressure & Temperature Correction. |
07. |
Turndown MFM 100: 1, MFC 50: 1. |
08. |
Taking Capillary Heat Sensing Technology |
09. |
Stability And Reliability Optimized For Long-Term Process Control |
10. |
Applies MultiFlow Technology With Multi Gas And Multi Range Functionality |
Product Parameters
Item |
MFC(Gas Mass Flow Controller) |
Flow Rate |
10sccm-200slm
300slm-3000slm |
Accuracy |
±1.0%F.S. |
0. 05% of Full Scale Per °C |
Linearity |
±0.5%F.S. |
Repeatability |
0.2%F.S. |
Response Time |
<2S |
Analog Output |
0-5V / 4-20mA / 0-10V |
Digital Communication |
RS485 Modbus RTU |
Power |
±15V / 24V |
Process Temperature |
0-50ºC |
Process Pressure |
Differential Pressure Requirement: 0.05-1.0Mpa |
Inlet Maximum |
3Mpa / 10Mpa |
Electrical Connections |
DB15 |
Leakage Rate |
1*10-8SCCSHe |
Temperature Coefficient |
±0.015%F.S. / Deg.C |
Base Material |
SS 316L |
Sealing Material |
CR, NBR, PTFE |
Process Connection |
1/4" / 3/8" / 6mm / 10mm |
Outline Dimension
Selection Table
Company |
HG |
Model |
AMFC (Anglog Gas Mass Flow Controller) |
GMFC (Digital Gas Mass Flow Controller) |
Output |
V0: 0-5V |
C4: 4-20mA |
R2: RS 232 |
R4: RS 485 |
Flow Range |
F0: 0-10 sccm |
F1: 10sccm-20slm |
F2: 20-100 slm |
F3: 100-200 slm |
F3: 100-200 slm |
F5: 500-1000 slm |
F6: 1000-2000 slm |
F7: 2000-3000 slm |
Display |
N: No display |
D: LCD display |
Process connection |
C1: Swagelok φ 6 |
C2: Swagelok φ 8 |
C3: VCR 1/4" |
C4: VCR 3/8" |
F: DN 25 Flange |
O: Other |