Digital New Liquid Oil Target Flow Meter for Glycerine Measurement

Product Details
Customization: Available
After-sales Service: Maintenance & Refund
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
101~500 square meters
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
  • Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Find Similar Products
  • Overview
  • Features
  • Product Parameters
  • Measuring Range & Pressure
  • Outline Dimension
  • Selection Table
  • Company Profile
Overview

Basic Info.

Model NO.
HG-TFM
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Size
DN6-DN5000mm
Sensor
Thread / Flange / Clamp on
Application
Industrial Production
Type
Digital Target Flow Meter
Measuring Media
Liquid
Measuring Principle
Capacitive Force Inductive Flowmeter
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Line Size
DN6-DN5000mm
Working Temperature
-200 - 500 Deg.C
Working Pressure
0.6-42MPa
Housing Material
Ss 304, Ss 316L
Relative Humidity
5% -95%
Power Supply
DC12-24V, 3.6V Lithium Battery
Protection Level
IP65, IP67
Ambient Temperature
-20 - 55 Deg.C
Medium
Liquid, Gas, and Steam
Signal Output
Pulse,4-20mA, RS 485, RS232, Hart
Signal Transmission Distance
1,000m
Configuration
Integral Type, Remote Type, Plug-in Type
Connection
Flange, Thread, Tri-Clamp on
Explosion Proof
Exdii Bt 4, Exiaii CT4
Transport Package
13kg
Specification
28*28*40cm
Trademark
Siko Instruments
Origin
China
HS Code
9026100000
Production Capacity
999 Units / Weeks

Packaging & Delivery

Package Size
25.00cm * 25.00cm * 40.00cm
Package Gross Weight
13.000kg

Product Description

Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
 
HG-TFM Series Capacitive Target Flow Meter Based On The Traditional Target Flow Meter, With The Development Of New Sensors, Microelectronics Technology Research And Development Into A New Type Capacitance Induction Flowmeter, It Has Both Orifice Plate, Vortex Flowmeter With The Characterstics Of The Moving Parts, And Also Has The Very High Sensitivity And Accuracy Comparable To Volumtric Flowmeter.

Adopts Chip Level Capactive Force Sensor, The Highly Effective Resistance To Overload Structure Design Is The Product Realize High Precision, High Stability, The Key To The Core, Combined With It'S Unique Anti-Inteference, Impurity Resistance.

In Addition To Substitute The Conventional Flow Measurement Problems, Especially In The High Viscosity, Dirty Media, Smudgy Medium, Easy To Condensing And Plugging, High Temperature, Low Temperature, Strong Corrosion And Other Flow Measurement Have A Good Adaptability In The Difficult Working Conditions.

Widely Used In Petroleum, Chemical, Metallurgy, Electric Power, Pharmaceutical, Environmental Protection, Food And Other Fields.

  * Wide Range Of Applicable Pipe Diameter: Φ10-Φ2000 To Larger.
  * Wide Temperature Range: -196°C - 500°C.
  * Suitable For High/Low Pressure Conditions: 0-42Mpa.
  * Suitable For All Kinds Of Media: Gas. Liquid ( Including High Viscosity Liquid, Slurry ), Steam.
  * Suitable For Low Flow Medium. The Lowest Flow Rate Can Be Measured Is 0.08m/s.
 
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
 
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement


 
Features


 
01.  The Whole Instrument Structure Is Solid Without Moving Parts & Easy To Disassemble.
02.  Variety Of Anti-Corrosion And High And Low Temperature Resistance Materials (Such As Hastelloy. Titanium.... etc.) Optional.
03.  The Whole Instrument Can Be Made Fully Sealed Without Dead Angle (Welding Form) &  Without Any Leakage Point &   Withstand 42Mpa High Pressure.
04.  Small Pressure Loss & Only About 1/2△P Of The Standard Orifice Plate.
05.  Anti-Interference & Strong Anti-Impurity Ability & Self-Test Program.
06.  Sensor Measurement No Contact With The Measured Medium & No Parts Wear & Safe And Reliable Use.
07.  Dry Calibration Method Available & Weight Hanging Method. Single Key Operation Can Complete The Calibration.
08.  Variety Of Installation Methods & Such As Online Plug-In & Low Installation Cost,
09.  Integrated Temperature & Pressure Compensation & Direct Output Quality Or Standard.
10.  Optional Small Signal Cutting &  Nonlinear Correction & Filtering Time Can Be Selected.
11.  Accurately Measure A Variety Of Normal Temperature & High Temperature 500 Degrees & Low Temperature -200 Degrees - Under The Condition Of Gas & Liquid Flow.
12.  Accurate Measurement & 0.2%F.S. & Easy To Install & Maintain.
13.  Good Repeatability & Generally 0.05% - 0.08% & Fast Measurement.
14.  The Range Can Be Changed According To The Actual Need To Replace The Choke (Target).
15.  Low-Power Battery Field Display. Can Directly Read The Value Online.
 The Display Can Read Instantaneous And Cumulative Flow And Percentage Bar Chart At The Same Time.
16.  Variety Of Output Signal & Can Transmit A Variety Of Parameters.
17.  Strong Seismic Resistance & Pulsating Flow Can Be Measured Within A Certain Range.


Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Product Parameters

Digital New Liquid Oil Target Flow Meter for Glycerine Measurement

Measuring Range & Pressure
Nominal Diameter
DN (mm)
Measuring Range
(m
3/H)
Target Diameter
Ratio Range
Maximum Pressure
 
Drop (kPa)
15 0.1 - 3 0.8 - 0.5 75.53
20 0.17 - 5 0.8 - 0.5 55.12
25 0.3 - 9 0.8 - 0.4 34.45
32 0.5 - 14 0.8 - 0.3 24.12
40 1.0 - 24 0.8 - 0.3 17.23
50 1.5 - 40 0.8 - 0.3 6.89
65 2.5 - 60 0.7 - 0.35 5.51
80 3.5 - 90 0.7 - 0.35 4.31
100 5 - 140 0.7 - 0.3 2.76
125 6 - 200 0.7 - 0.3 2.07
150 10 - 300 0.6 - 0.25 1.38
200 18 - 560 0.6 - 0.25 0.89
250 25 - 800 0.5 - 0.25 0.56
300 40 - 1200 0.5 - 0.2 0.35
350 50 - 1500 0.5 - 0.2 0.10
400 65 - 2000 0.5 - 0.2 0.07
450 90 - 2600 0.4 - 0.2 0.06
500 110 - 3300 0.4 - 0.2 0.05
550 140 - 4100 0.35 - 0.2 0.04
600 170 - 5000 0.3 - 0.15 0.03
700 230 - 6800 0.3 - 0.15 0.011
800 300 - 9000 0.3 - 0.15 0.0083
900 370 - 11000 0.3 - 0.15 0.0062
1000 470 - 14.000 0.2 - 0.1 0.0055
1100 560 - 16.000 0.2 - 0.1 0.0041
1200 670 - 20000 0.2 - 0.1 0.0034
1300 780 - 23.000 0.2 - 0.1 0.0028
1400 900 - 27.000 0.2 - 0.1 0.0018
1500 1050 - 31000 0.2 - 0.1 0.0016
1600 1200 - 32500 0.2 - 0.1 0.0014
1700 1350 - 36500 0.2 - 0.1 0.0012
1800 1510 - 40800 0.2 - 0.1 0.0011
1900 1680 - 45.500 0.2 - 0.1 0.0010
2000 1850 - 50000 0.2 - 0.1 0.0009
2100 1980 - 55800 0.2 - 0.1 0.0008

 

Outline Dimension
 
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Nominal Diameter DN(mm) Total
Width
Total Height Nominal Diameter DN(mm) Total Width Total Height
A B A B
15 150 345 125 200 455
20 150 350 150 200 480
25 150 355 200 250 530
32 150 362 250 250 580
40 150 370 300 250 630
50 150 380 350 250 680
65 200 395 400 250 730
80 200 410 450 250 780
100 200 430 500 250 830

Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement


 
Selection Table
 
HG-TFM -  
Capacitive
Target Type
 
  Code  Nominal
 Diameter
 0010  DN10
 0100  DN100
 ...  
 5000  DN5000
  Code  Process Connection
   F Flange Pipe C Plug-in D Wafer U Inline Disassembly Type L Thread Type E Other
   Code  Type of Medium
   L Liquid G Gas S Steam
  Code  Pressure Rating
A 0.6Mpa E 2.5Mpa I 10 Mpa M 20Mpa
B 1.0 Mpa F 4.0 Mpa J 11 Mpa N 25 Mpa
C 1.6Mpa G 5.0 Mpa K 15 Mpa O 26 Mpa
D 2.0 Mpa H 6.3Mpa L 16 Mpa P 42 Mpa
  Code
 Medium Temperature
C   -20 To 80°C (Room Temperature)
Z  80 To 200°C (Medium Temperature)
G  200 To 450°C (High Temperature)
D  -200 To -20°C (Low Temperature)
  Code  Output Signal
P   Pulse H  HART Protocol
I  4-20mA K  Relay Output
R  Communication Output
  Code   Explosion-proof Identification
A Intrinsic Safety Type D  Flameproof Type
  Code  Shell Material
C  Carbon Steel
S  304 Stainless Steel
T  316L Stainless Steel
  Code  Sensor Material
H    Hastelloy
T  Titanium
S  304 Stainless Steel
E  Other Material
 
Company Profile
 
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement
Digital New Liquid Oil Target Flow Meter for Glycerine Measurement

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More