Customization: | Available |
---|---|
After-sales Service: | Maintenance & Refund |
Type: | Spectrometer Spectral Illuminance Meter |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LS330 Spectral Illuminance Meter Is A Versatile Instrument Designed With A Spectral Sensor. It Is Used For Measuring Illuminance, Uv Index, Flicker Frequency, Standard Deviation Of Color Matching (Sdcm), Color Rendering Index (Cri), Correlated Color Temperature (Cct), Blue Light Hazard Ratio, Temperature, And Humidity In Various Scenarios Such As Lamps And Lanterns Lighting, Outdoor Lighting, Greenhouse Lighting, And Stage Lighting.
The Instrument Also Can Display The Spectral Curve, Which Helps Identify The Type Of Lighting Fixture.The Instrument Also Has A Plant Illumination Mode, Which Is Specially Designed For Plant Growth Environments. It Can Accurately Measurephotosynthetic Photon Flux Density(Ppfd), Ppfd (Blue), Ppfd (Green), Ppfd (Red), Yield Photon Flux Density (Ypfd), Chlorophyll-A, And Chlorophyll-B, Helping Users Understand And Optimize Light Management During The Planting Process And Improve Plant Growth Efficiency. It Is Suitable For Home Gardening, Plant Factories, Greenhouses, Agricultural Research, Plant Lighting, And Other Fields.
* Measurement Of Lux, Cct, Uvi And Other Parameters.
* Multi-Mode, Multi-Parameter Measurement For Broader Applications.
* Equipped With Plant Mode,Accurately Detect Ppfd.
* 1,000,000Lux Ultra-Large Range Design.
* High Precision, Pass Authoritative Metrology Inspection.
Application
01. Probe Specifications And Parameters
Parameters | Value |
---|---|
Illuminance Wavelength Range | 400nm - 700nm |
Illuminance Wavelength Interval | 10nm |
Illuminance Measurement Range | 0 - 1000000Lux |
Illuminance Resolution | 0.1Lux |
Illuminance Measurement Accuracy |
≤±(3%H + 2 Lux) (H is The Standard Value, Calibrated Under CIE Standard A Light Source) |
Illuminance Unit Options | Lux (Default), FC |
Correlated Color Temperature Measurement Range |
1000 - 100000K |
UV Index Measurement Range | 0.0 - 15.0 |
Flicker Frequency Measurement Range | 10 - 500HZ |
Temperature Measurement Accuracy | ±0.5ºC |
Humidity Measurement Accuracy | ±4%RH |
PPFD Measurement Range | 0 - 10000 μmol/m²/s |
PPFD Measurement Accuracy | ≤±(5%H+0.5 μmol/m²/s) |
PPFD (Blue) Measurement Range | 0 - 5000 μmol/m²/s |
PPFD (Blue) Measurement Accuracy | ≤±(10%H+0.5 μmol/m²/s) |
PPFD (Green) Measurement Range | 0 - 5000 μmol/m²/s |
PPFD (Green) Measurement Accuracy | ≤±(10%H+0.5 μmol /m²/s) |
PPFD (Red) Measurement Range | 0 - 5000 μmol/m²/s |
PPFD (Red) Measurement Accuracy | ≤±(10%H+0.5 μmol /m²/s) |
YPFD Measurement Range | 0 - 10000 μmol/m²/s |
YPFD Measurement Accuracy | ≤±(5%H+0.5 μmol /m²/s) |
Chlorophyll-a Measurement Range | 0 - 10000μW/cm² |
Chlorophyll-a Measurement Accuracy | 1.≤±(10%H+0.5μW/cm²) |
Chlorophyll-b Measurement Range | 0 - 10000μW/cm² |
Chlorophyll-b Measurement Accuracy | ≤±(10%H+0.5μW/cm²) |
Response Time | <0.7s |
Test Aperture Diameter | Φ21mm |
Size | Length 188.5mm Width 75.2mm Height 30.3mm |
Weight | About 232g (Including Batteries) |
Display | 240*160 Dot Matrix LCD |
Power Supply | 2 AA Alkaline Batteries |
Operating Environment | Temperature 0 - 40ºC Humidity <85%RH |
01. Multi-Parameter & Wider Application.
---
In Normal Mode, The Instrument Measures Parameters Like Illumination, Cct, Flicker Frequency, Uv Index, Sdcm, Cri, Temperature, And Humidity To Evaluate Lighting Characteristics. In Plant Mode, It Accurately Measures Ppfd, Ypfd, Chlorophyll-A, And Chlorophyll-B To Optimize Plant Lighting For Better Quality And Yield.
02. Freely Switch Between Normal And Plant Modes.
---
The Instrument Offers Both Normal And Plant Illumination Modes, Meeting Diverse Measurement Needs. It Handles Both Everyday Lighting Detection And Plant Growth Parameters (E.G., Ppfd, Chlorophyll Content), Helping Users Optimize Lighting In Various Scenarios.
No. | Description | Quantity | Unit |
---|---|---|---|
1 | Spectral Illuminance Meter | 1 | pcs |
2 | User Manual | 1 | pcs |
3 | Calibration Report | 1 | pcs |
4 | Certificate/Warranty Card | 1 | pcs |
Q1: What Is An Illuminance Meter ?
A1: An Illuminance Meter, Also Known As An Illumination Meter, Light Meter Or Lux Meter, Is A Specialized Instrument Used To Measure The Amount Of Light That Falls On A Surface. It Provides Readings In Lux (Lx) Or Foot-Candles (Fc), Helping Users Evaluate Lighting Conditions For Various Applications, Such As Workplace Safety, Photography, Architectural Design, And Industrial Lighting Assessments.
Modern Illuminance Meters Come In Different Types, Including Spectral Illuminance Meters, Which Can Analyze Light Across Different Wavelengths For Precise Measurement, And Standard Lux Meters, Which Provide General Light Intensity Readings. Some Advanced Models Also Feature Data Logging, Multiple Measurement Modes, And Bluetooth Connection, Making Them Suitable For Scientific Research And Professional Applications. Linshang Latest Ls330 Spectral Illuminance Meter Has Almost All Of The Above Functions, And Is Suitable For A Variety Of Applications.
Whether For Ensuring Compliance With Lighting Standards, Optimizing Energy Efficiency, Or Enhancing Visual Comfort, An Illumination Meter Is An Essential Tool For Accurate And Reliable Light Measurement.
Q2: Types of Illuminance Meters
A2: Illuminance Meters Come In Various Types, Each Designed For Specific Measurement Needs. The Table Below Provides A Comparison Of Different Types Of Illuminance Meters:
Type |
Description |
Key Features |
Applications |
Standard Illuminance |
Measures General Light Intensity In Lux or Foot-Candles. |
- Basic Light Measurement. - Compact And Easy To Use. - Affordable. |
- Indoor and Outdoor Lighting Assessment. - Workplace And office Lighting Compliance. |
LS330 Spectral |
Measures Light Intensity Across Different Wavelengths, Providing Spectral Data. |
- High Precision. - Measures Color Temperature & Spectrum. - Cost-effctive. |
- Normal and Plant Modes. - Data Logging. - LED and OLED Lighting Analysis. |
LS331 Black |
Measures Ultraviolet (UV) Light Intensity, Often Used For UV-A Applications. |
- Specialized For |
- Magnetic Particle Testing. -Penetration Testing. |
Each Type Of Illumination Meter Serves A Specific Purpose, Whether For Basic Lighting Assessments, Precise Spectral Analysis, Or Uv Light Measurement. Choosing The Right Illuminance Meter Depends On The Specific Needs Of The Application.